Our office will be closed December 25 and 26, 2024 and January 1, 2025, we will close at noon on December. 24 and 31 for the holidays.

Meter Proving Products

Meter Prover Sphere Sizing Rings

We offer a wide range of sizing rings to ensure the prover spheres are inflated to the correct size for your pipeline.

Product Options

Can be used as:
Meter Prover Accessories

See technical information below

Actual operational experience with the spheres will allow more accurate sizing for any given pipeline or meter power.

  • Urethane – 1% larger than pipe ID
  • All other compounds – 2% larger than pipe ID
  • Remove quick coupling from pressure hose end and thread it into filling adapter.
  • Fill reservoir on pump with suggested liquid and operate pump until all air is removed from the pump and the hose before connecting filling adapter to sphere.
  • Connect hose filling adapter and proceed to size sphere to proper diameter.
  • After reaching proper size, pressure may be relieved from filler hose with small hand valve.
  • Remove filling adapter from sphere valve.
  • Firmly replace valve cap.

Precautions necessary when sizing spheres:

  • Insure all air is evacuated from the sphere during filling and sizing.
  • Tighten all valve and valve caps firmly, but do not force threads.
  • If valve leakage occurs, replace entire sphere valve assembly if necessary.
  • Custom made to your exact requirements
  • 24 hour shipment
  • Precision laser cut from 1/4” Micarta (advise pipe size, schedule and percent oversize required)

Sphere Sizing Recommendations

Actual operational experience with the spheres will allow more accurate sizing for any given pipeline or meter power.

  • Urethane – 1% larger than pipe ID
  • All other compounds – 2% larger than pipe ID

Sizing Instructions

  • Remove quick coupling from pressure hose end and thread it into filling adapter.
  • Fill reservoir on pump with suggested liquid and operate pump until all air is removed from the pump and the hose before connecting filling adapter to sphere.
  • Connect hose filling adapter and proceed to size sphere to proper diameter.
  • After reaching proper size, pressure may be relieved from filler hose with small hand valve.
  • Remove filling adapter from sphere valve.
  • Firmly replace valve cap.

Precautions necessary when sizing spheres:

  • Insure all air is evacuated from the sphere during filling and sizing.
  • Tighten all valve and valve caps firmly, but do not force threads.
  • If valve leakage occurs, replace entire sphere valve assembly if necessary.

Features

  • Custom made to your exact requirements
  • 24 hour shipment
  • Precision laser cut from 1/4” Micarta (advise pipe size, schedule and percent oversize required)

We're Meter Proving Experts

Here is the value we bring to you

You’re not buying just a product, our expertise comes with every purchase.

Our decades of hands-on field experience from unconventional environments to compliance and safety, allows us to understand what you need down to the smallest detail.

Want to talk?

Call +1 403-287-3558

Or use our online form ›